Wireless
Specification compliance IEEE 802.11a, 11b, 11g, 11n
Receive Channel Frequencies

2.4 GHz Band*
2412-2484 MHz (Channel 1 to Channel 14)

5 GHz Band*
5170-5320 MHz, 5500-5700 MHz, 5745-5825 MHz (Channels 34, 36, 38, 40, 42, 44, 46, 48, 52, 56, 60, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140, 149, 153, 157, 161, 165)

*Notes:
1. AirCheck receives on all of these frequencies in every country.
2. These are the center frequencies of the channels that AirCheck supports.

Transmit Channel Frequencies

2.4 GHz Band**
802.11b
2412-2484 MHz (Channel 1 to Channel 14)

802.11 g/n 20 MHz BW (HT20)
2412-2472 MHz (Channel 1 to Channel 13)

802.11n 40 MHz BW (HT40)
2422-2462 MHz (All legal bonded channel pair combinations)

5GHz Band**
802.11 a /n 20 MHz BW (HT20)
5180-5320 MHz, 5500-5700 MHz, 5745-5825 MHz (Channels 36, 40, 44, 48, 52, 56, 60, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140, 149, 153, 157, 161, 165)

802.11 n 40 MHz BW (HT40)
5190-5310, 5510-5670, 5755-5795 (All legal bonded channel pair combinations)

**Notes:
1. AirCheck transmits only on frequencies allowed in the country where it operates.
2. These are the center frequencies of the channels that AirCheck supports.

Regulatory Domain World Mode, 802.11d compliant
External Directional Antenna
Frequencies Frequency range 2.4 GHz to 2.5 GHz and 4.9 to 5.9 GHz 
Minimum gain 5.0 dBi in the 2.4 GHz band and 7.0 dBi in the 5 GHz band
Connector Reverse-polarity SMA plug
Environmental Specifications
Operating Temperature 32 to 113ºF (0 to 45ºC)
Note: The battery will not charge if the internal temperature of the tester is above 113ºF (45ºC)
Operating Humidity (% RH without condensation) 90% (50 to 95ºF; 10 to 35ºC)
75% (95 to 113ºF; 35 to 45ºC)
Storage temperature -4 to 140ºF (-20 to 60ºC)
Shock and vibration Random, 2g, 5 Hz-500 Hz (Class 2) 1 m drop test
Safety EN 61010-1 2nd edition
Altitude Usage up to: 4,000 m; Storage: 12,000 m
EMC FCC Part 15 Class A, EN 61326-1
Certifications and Compliance Conforms to relevant European Union directives
Listed by the Canadian Standards Association
Conforms to relevant Australian standards
Conforms to FCC Rules, Parts 15.107, 15.109
General
Dimensions 3.5 in x 7.8 in x 1.9 in (8.9 cm x 19.8 cm x 4.8 cm)
Weight 14 oz (0.4 kg)
Battery Removable, rechargeable lithium-ion battery pack (18.5 Watt-hrs)
Battery life Typical operating life is 5.5 hours. Typical charge time is 3 hours.
External AC adapter/charger AC input 90-264 Vac 48-62 Hz input power DC output 15 Vdc at 1.2 amps
Display 2.8 in color LCD (320 x 240 pixels)
Keypad 12-key elastomeric
LEDs 2 LEDs (transmit and link Indicators)
Host interface USB 5-pin mini-B
Wireless antenna Internal
External antenna port Input only. Reverse-polarity SMA connector.